Spiroergometry - Respiratory gas analysis Spiroergometry - Respiratory gas analysis

Spiroergometry

Spiroergometry

Respiratory gas analysis reveals endurance performance and is used to determine training intensities

Dr. Mario Weichenberger, Preventive and Rehabilitative Sports Medicine, Technical University of Munich


Physical Activity, Energy Metabolism, and Oxygen Absorption

Movement during physical activity is only possible due to complex interaction between different skeletal muscles. The energy required for muscle contractions can be produced anaerobically (without oxygen) with a significant increase in lactate concentration in the blood or during oxygen consumption through the so-called aerobic burning of carbohydrates (glucose) or fats (fatty acids). With increasing intensity of physical activity (e.g., during endurance exercise), the energy demand of the muscle cell increases, which is covered by an increase in oxygen absorption. The more oxygen working muscles can absorb, the more energy can be supplied for muscle contractions and the greater the maximum endurance capacity is.

Pierre Chazan
Your Contact for IR detectors
Click here

Respiratory gas analysis

with IR detectors

The respiratory gas analysis reveals the endurance performance and is used to determine the training intensity

Factors Influencing Oxygen Absorption
The oxygen absorption of humans depends on the exchange of gas between the lungs and blood, the oxygen transportation capacity of the blood (hemoglobin), the distribution of blood in the body (circulation), and the oxygen absorption capacity of muscle cells (mitochondria density and aerobic enzyme capacity). Endurance training improves all of these influential factors. For this reason, endurance athletes feature particularly high maximum oxygen absorption (VO2max or VO2peak).

Oxygen Absorption and Carbon Dioxide Release
nhaled air and exhaled air differ in particular in their concentration of oxygen and carbon dioxide: While inhaled air is rich in oxygen (O2) and contains little carbon dioxide (CO2), the composition of exhaled air is exactly the opposite. The difference is due to the fact that the skeletal muscle consumes oxygen during physical activity and releases CO2. Depending on the intensity of physical activity, the breakdown of glucose and fatty acids described above produces different amounts of CO2. Based on the ratio of CO2 release and O2 absorption (respiratory exchange ratio), it is possible to analyze which form of energy supply dominates and how high the percentage of metabolized substrates is. This makes it possible to obtain the optimal training intensity or percentage of fat burning at different exercise intensities.
The measurement of O2 absorption and CO2 release during physical exercise makes a differential analysis of the function and performance of the lungs, the circulatory system, and the exchange of gas in the body possible and is, therefore, of particular importance for both patients and athletes in performance diagnostics and optimization.

Cardiopulmonary Exercise Testing – Analysis of Oxygen Absorption during Exertion
Cardiopulmonary exercise testing is a diagnostic method in which respiratory gas analysis is carried out during increasing exertion, generally on a bicycle or treadmill ergometer (ergometry: from the Greek, ergon means work and metron means to measure). The physical exertion starts out very low and is continually increased for a timespan of approximately eight to twelve minutes to physical exhaustion. During the physical exertion, the test person wears a breathing mask over his/her mouth and nose and the concentration of oxygen and carbon dioxide in the inhaled and exhaled air, the breathing frequency, the tidal volume, the respiratory minute volume (breathing ­frequency x tidal volume), and the heart rate are continually analyzed. 

Thanks to modern measurement technology, all measurement parameters are shown in real time, which makes it possible to carry out a detailed analysis during the physical exertion.

Results of Cardiopulmonary Exercise Testing
The maximum oxygen absorption (­VO2max) achieved at the end of the endurance test is an important indicator in determining endurance capacity. The best endurance athletes achieve VO2max values of up to 80 ml/min/kg, whereas non-athletes can absorb only approximately 45 ml/min/kg of oxygen. In addition, based on changes, for ­example, in the relationship between oxygen absorption (VO2) and carbon dioxide release (VCO2) or in the relationship between respiratory minute volume (V’E) and carbon dioxide release (VCO2), so-called ventilatory thresholds can be determined. With the help of so-called 9-panel-plot according to K. Wasserman, the thresholds can be determined and other changes analyzed during the endurance test (see Fig.). The ventilatory thresholds can be used to determine optimal training intensity and are, therefore, of particular importance when managing endurance training for patients and athletes. Cardiopulmonary exercise testing is, therefore, particularly well-suited for both the differential analysis of performance and training management. For this reason, it is commonly used in sports medicine.

Technical University of Munich Team
The chair of the preventive and rehabilitative sports medicine department at the University Hospital rechts der Isar of the Technical University of Munich (executive medical director and university professor, Prof. Dr. Martin Halle) offers state-of-the-art university hospital diagnostics combined with highly-qualified medical and sports science know-how at both sites – in Olympiapark and at the hospital rechts der Isar. Each individual – from patients to professional athletes – receives optimal medical care and advice, including a personal recommendation regarding exercise, training, and nutrition.

www.sport.med.tum.de

Product Selection

for spiroergometry

Infrared Components Infrared Components
55+ Series: IR Components for 5Hz / 5µm

Complete with selected filter and other accessories.

A perfect match: The ideal emissivity of Infrasolid emitters complement the high dynamic range and low noise of our custom-made pyrodetectors.
IA35 Series InAs 900 - 3500 nm IA35 Series InAs 900 - 3500 nm
InAs 900 - 3500 nm

The IA35 series photodiodes based on heterostructures were specially designed for operation at room temperature.

New
IG22X250T7 IG22X250T7
InGaAs Photodiodes 500 - 2600 nm

Infrared (IR) photodiodes with an emphasis on quantum efficiency

LASER COMPONENTS develops and manufactures photodiodes in the spectral range of up to 2600 nm in the Near-Infrared (NIR).
PbS lead selenide infrared detector PB25S30309S PbS lead selenide infrared detector PB25S30309S
PbS Detectors

PbS Detectors detect infrared radiation in the wavelength range between 1 µm and 3.3 µm.

PbS detectors offer high sensitivity at a low price. They are the perfect solution for large-area IR detectors.
PbSe lead selenide infrared detector PB55S1010T2S8L PbSe lead selenide infrared detector PB55S1010T2S8L
PbSe Detectors

Polycrystalline lead selenide (PbSe) is a standard semiconductor detector with a sensitivity of between 1 µm and 5.2 µm.

New
ALUT3151X1300-k2 ALUT3151X1300-k2
Advanced LTO Infrared Detectors

Advanced single channel voltage mode detectors for FTIR instruments.

Excellent linearity and fast response to IR flux change.
Choice of Filters for Pyroelectric Detectors

An IR filter makes all the difference. Thermal detectors are naturally polychromatic, and a filter is needed to detect specific gases/wavelengths.

Differential Pyroelectric Detector Differential Pyroelectric Detector
Differential Pyroelectric Detector

Pyroelectric crystals generate positive and negative charge carriers simultaneously on opposing sides.

The LD21XX and DD31XX series are exclusive pyroelectric detectors in which both crystal sides are amplified separately.
Digital Dual Thermopile ST60 Digital Dual Thermopile ST60
Miniature Thermopiles

The best D* in thermopiles is achieved with this arrangement.

Multi channel pyroelectric detectors Multi channel pyroelectric detectors
Multi-channel LiTaO3 Pyroelectric Detectors

Multi-channel pyrodetectors: dual-channel, triple-channel and quad-channel versions are available.

Single Channel Current Mode Pyroelectric Detector Single Channel Current Mode Pyroelectric Detector
One-Channel LiTaO3 Pyroelectric Detector

Single channel pyroelectric detectors made of LiTaO3 are available for current mode (CM). They are used for gas detection and flame detection.

New
PR N°1 THz, Pyro Receiver, THz PR N°1 THz, Pyro Receiver, THz
PR Series - IR THz Receivers

COMPACT AND UNIVERSAL receivers with high quality electronics for the LWIR and THz range.

Uncooled device made for THz detection or spectroscopic applications in FTIR instruments. 

LASER COMPONENTS France - Your competent partner for optical and optoelectronic components in France.

Welcome to LASER COMPONENTS S.A.S., your expert for photonics components. Each product in our wide range of detectors, laser diodes, laser modules, optics, fiber optics, and more is worth every Euro (€/EUR). Our customized solutions cover all conceivable areas of application: from sensor technology to medical technology. You can reach us here:

45 Bis Route des Gardes
92190 Meudon
France

Phone: +33 (0) 139 595 225
Email: serviceclient(at)lasercomponents.fr

Team of experts
You have questions or need our support?
Please call us.
Pierre Chazan
Senior Business Development Manager
Pierre Chazan
LASER COMPONENTS S.A.S.
92190 Meudon
Contact Form
You would like to send us something? You can reach us by phone and by e-mail.

Laser Components

45 Bis Route des Gardes
92190 Meudon
France

Phone: +33 (0) 139 595 225

You will be redirected
to the Fiber Technology Website ...